Solenoid valve life test bench
Free Shipping
For all orders over $200
Solution
Provide specific feasible solutions
Distribution
Supply product distribution
Hotline Order:
+86 400-816-6687
+86 13316038150
Solenoid Valve Life Test Bench (12 stations)
- Basic requirements: suitable for durability testing of solenoid valves at room temperature/hot water inlet and outlet of water purification equipment;
- Equipment function: meet the technical requirements specified in the standards such as “QB/T 4144 Reverse osmosis Water Purifier for Household and Similar Purposes”.
Beg;
- Test content: It is mainly used for the durability test of water inlet solenoid valve and waste water solenoid valve of water purification equipment.
Standard test: test water temperature (20±5) °C, hot water (95±5) °C. Connect the solenoid valve to the test set, use the gauge
The digital electronic control board controls the on/off of the solenoid valve by controlling the tap water on/off through the solenoid valve, and records the number of switches and switches for 100,000 times
Close test to monitor whether the solenoid valve is working properly throughout its life. Meet the standard test, and reserve the test variable can be adjusted.
- Technical Parameters
4.1 stations: 12 stations (4 of which can be used for wastewater valve testing, similar products can be tested together, different categories.)
No), the same pressure source, using a ball valve input;
4.2 Water tanks: 2 x 100L water tanks (one room temperature water tank; A heated water tank with adjustable temperature. It can be switched automatically according to the settings
Water tank), material 304, thickness ≥1.2mm;
4.3 Test pressure: 0.05~0.8MPa;
4.4 Pressure sensor: 0-1.0MPa, brand requirements: GE; Accuracy requirements ± 0.2%F.S.
4.5 Effluent flow meter: 0.2-3L/min accuracy±2%F.S.;
4.6 Turn-on time: 0-9999s adjustable.
4.7 Disconnect time: 0-9999s adjustable.
4.8 Number of tests: 0-999999 times adjustable.
4.9 Adjustable power supply is configured to ensure the current capacity of 1A per station, and DC is adjustable from 0-60V.
4.10 Temperature sensor: (0-120)°C, accuracy ± 0.5%F.S
- Comprehensive performance of the equipment
5.1 Water inlet solenoid valve test: use constant pressure water supply system to ensure that the pressure before testing the booster pump is stable at the set pressure, and use high precision
The degree pressure sensor feeds back the constant pressure water supply pressure, and uses the buffer water tank to stabilize the pressure fluctuations caused by the opening and closing of multiple solenoid valves, in accordance with
The set on-on and disconnection time are used for life testing, and the test valve is judged to be open according to the feedback of the flowmeter after the valve is opened.
5.2 Wastewater solenoid valve test: use constant pressure water supply system to ensure that the pressure before testing the booster pump is stable at the set pressure, and use high precision
The degree pressure sensor feeds back the constant pressure water supply pressure, and uses the buffer water tank to stabilize the pressure fluctuations caused by the opening and closing of multiple solenoid valves, in accordance with
The set on-on time and disconnection time are used for life test, and after the valve is opened, judge whether the test valve is flushed according to the feedback of the flowmeter.
After closing the valve, judge whether the test valve is in a water production state according to the feedback of the flowmeter.
5.3 During the product test, if the test fault tolerance is reached, the test will be automatically stopped, and the prompt light will be on to remind the operator to proceed
Dispose.
5.4 Console: Using PLC control, the number of tests, opening time and closing time are set on the computer, and the interface displays the cumulative tests
times, and the current running status.
5.5 Safety protection: The water tank has the functions of overflow, leakage and low water level protection, etc.
5.6 The water used by this equipment is self-recycling. When the water temperature in the water tank is too high, the water can be changed automatically.
5.7 Equipped with water temperature heating device, suitable for durability test of hot water solenoid valve.
- Other requirements: The equipment pipe material is made of 304 stainless steel.
Zhipinhui after-sales service
Equipment after-sales policy:
*Equipment warranty period: One Year
*After sales hotline: 4008166687
1. Our company has assembled a team of experienced on-site engineers and senior technicians who can respond promptly to any equipment issues and provide after-sales maintenance.
2. Within one week of the delivery of the new product, our after-sales technical department staff will provide installation and after-sales training for the equipment at the customer’s location based on the contact information and address provided by the customer.
3. All complaints related to product quality will be responded to within 1 hour. Within 3-5 hours within the province and 24-48 hours outside the province, the customer will arrive at the scene and determine the handling measures based on the complaint situation, and carry out after-sales maintenance.
4. To better address customers’ difficulties and concerns, our company promises that all maintenance personnel will be on call.
5. Any costs related to product quality during the shelf life will be borne by our company.
6. During the warranty period, we will provide free repairs due to improper use by your side or natural environment. The materials and accessories used for repairs will only be charged at cost price.
Related products
-
Electric kettle life test bench
Rated 0 out of 5(0) -
Electronic ice liner life test bench
Rated 0 out of 5(0) -
Thick film heating element life test bench
Rated 0 out of 5(0) -
Dc pump life test bench
Rated 0 out of 5(0)