This equipment is based on GB15287, GB15288, GB20234.1, GB2099, GB16915, GB15092, GB17465, GB11918, GB13140, GB14048, GB7251, UL310, UL498, UL817, UL941, UL1059, IEC60309, IEC60998, IEC60669, IEC61058, IEC60439, EIA-364-70 and other standards. It is mainly used for temperature rise test and fuse test of the electrical connection part of lithium battery structural parts under high current. According to the test environment temperature, high current overload and temperature rise monitoring under different ambient temperature conditions can be carried out.

  1. Computer program-controlled DC current source setting:
    Maximum output voltage: DC5V
    Output constant adjustable test current: DC10~300.0~3000.0A two-speed continuously adjustable
    Test current stability: ±(1% set value + 5 characters), response time 1S
    Current display accuracy: ±(0.3% reading + 5 characters)
    Impedance voltage display accuracy: ±(0.3% reading + 5 characters)
    2. Controller: Power on/off time: 1~99999 seconds
    Number of on/off times: 1~9999 times, with power off memory function, automatic shutdown when the number reaches
    3. Equipped with our independently developed TWC-2A multi-channel temperature tester, it can be tested with power on without damaging the instrument. The instrument uses Japanese imported relays to collect data, has strong anti-interference ability, and can accurately depict the temperature curve.
    4. Thermocouple temperature rise test: (low temperature test, scanning time 1S)
    Temperature measurement range: 0~260℃ Accuracy ±0.3% reading +1℃; Resolution: 0.1℃
    Temperature measurement: 8 channels (including 1 point to measure ambient temperature)
    Configuration of thermocouple: American Ω company T-type 30AWG fine-wire thermocouple, length 2 meters, a total of 8;
    Acquisition speed: 1 second/time
    5. Two-color infrared temperature test function: (high temperature acquisition)
    Imported configuration: American Fluke (monochromator)
    Temperature measurement channel: 1 channel
    Temperature measurement range: 50~1000℃, temperature resolution: 1℃ (low starting temperature, high environmental requirements)
    Response time: 20mS (95%)
    Repeat accuracy: 0.5%
    Adjustable distance: 300~600mm (distance between the object to be measured and the instrument)
    High-speed collector: completed by computer fast acquisition card

 

 

Zhipinhui after-sales service

Equipment after-sales policy:

*Equipment warranty period: One Year

*After sales hotline: 4008166687

1. Our company has assembled a team of experienced on-site engineers and senior technicians who can respond promptly to any equipment issues and provide after-sales maintenance.

2. Within one week of the delivery of the new product, our after-sales technical department staff will provide installation and after-sales training for the equipment at the customer’s location based on the contact information and address provided by the customer.

3. All complaints related to product quality will be responded to within 1 hour. Within 3-5 hours within the province and 24-48 hours outside the province, the customer will arrive at the scene and determine the handling measures based on the complaint situation, and carry out after-sales maintenance.

4. To better address customers’ difficulties and concerns, our company promises that all maintenance personnel will be on call.

5. Any costs related to product quality during the shelf life will be borne by our company.

6. During the warranty period, we will provide free repairs due to improper use by your side or natural environment. The materials and accessories used for repairs will only be charged at cost price.

Shopping Cart 0

No products in the cart.